AgileConnect Y, X and Reducer Connectors
Y and X connectors and straight reducers to branch, join, and adapt tubing lines
Single-use and bioprocessing
Connector, clamp, gasket and end cap
Hose barb connector, clamp, gasket, and end cap for single-use clamp joints
1 1/2″ clamp-to-hose-barb connectors, reinforced polypropylene clamps, silicone gaskets, and 3/4″ and 1 1/2″ clamp end caps for single-use systems.
The AgileConnect clamp set brings together the parts of a clamp joint in a single-use system: the clamp-to-hose-barb connector, the clamp, the silicone gasket, and the end cap for ports left unused.
The clamp-to-hose-barb connectors (CHB4 to CHB8) go from a standard 1 1/2″ clamp connection to 1/4″, 1/2″, 3/4″, or 1″ tubing. They are made of polypropylene suitable for food and drug contact, with a smooth inner surface for free flow and minimal entrapment. They are used to connect single-use bags to process equipment, in transfer and sampling manifolds, in aseptic filling, and to interconnect filters, sensors, and valves.
The clamps (CLC7 and CLC10) are made of lightweight reinforced polypropylene: they install without special tools, can be connected and disconnected repeatedly without deforming, and work on both plastic and metal connections. The gaskets (JC-0075-SIL and JC-0150-SIL) are latex-free medical-grade silicone, reusable or single-use depending on the process. The end caps (CBL7 and CBL10) close unused clamp ports and keep them sterile, or seal a port for a pressure test.
All parts can be sterilized in an autoclave at 121 °C or by gamma irradiation at 25 to 45 kGy, and they are double-bagged for entry into an ISO 7 cleanroom.
Hose barb connector, clamp, gasket, and end cap, designed to work together.
Connectors for 1/4″, 1/2″, 3/4″, and 1″ tubing, with a smooth inner surface: free flow and minimal entrapment.
Lightweight reinforced polypropylene. Connects and disconnects repeatedly without deforming, on plastic or metal connections.
Latex-free and TSE/BSE-free, compliant with USP <88> Class VI and FDA 21 CFR 177.2600. Reusable or single-use.
Closes unused ports and keeps them sterile, or seals a port for a pressure test.
All parts can be autoclaved at 121 °C or gamma irradiated at 25 to 45 kGy.
| Clamp-to-hose-barb connectors and end caps | Polypropylene |
|---|---|
| Clamps | Reinforced polypropylene |
| Gaskets | Medical-grade silicone, latex-free |
| Hose barb connectors | 1 1/2″ clamp to 1/4″, 1/2″, 3/4″, and 1″ tubing |
|---|---|
| Clamps, gaskets, and end caps | 3/4″ (19.05 mm) and 1 1/2″ (38.1 mm) clamp |
| Autoclave | 121 °C |
|---|---|
| Gamma irradiation | 25 to 45 kGy |
| Packaging | Double bag, for entry into an ISO 7 cleanroom |
|---|---|
| Standard pack | 10 units |
| Part number | Connection | Material | Sterilization |
|---|---|---|---|
| CHB4 | 1 1/2″ clamp to 1/4″ (6.4 mm) hose barb | Polypropylene | Autoclave or gamma |
| CHB6 | 1 1/2″ clamp to 1/2″ (12.7 mm) hose barb | Polypropylene | Autoclave or gamma |
| CHB7 | 1 1/2″ clamp to 3/4″ (19.05 mm) hose barb | Polypropylene | Autoclave or gamma |
| CHB8 | 1 1/2″ clamp to 1″ (25.4 mm) hose barb | Polypropylene | Autoclave or gamma |
| Part number | Clamp | Material | Sterilization |
|---|---|---|---|
| CLC7 | 3/4″ (19.05 mm) | Reinforced polypropylene | Autoclave or gamma |
| CLC10 | 1 1/2″ (38.1 mm) | Reinforced polypropylene | Autoclave or gamma |
| Part number | Clamp | Material | Sterilization |
|---|---|---|---|
| JC-0075-SIL | 3/4″ (19.05 mm) | Silicone | Autoclave or gamma |
| JC-0150-SIL | 1 1/2″ (38.1 mm) | Silicone | Autoclave or gamma |
| Part number | Clamp | Material | Sterilization |
|---|---|---|---|
| CBL7 | 3/4″ (19.05 mm) | Polypropylene | Autoclave or gamma |
| CBL10 | 1 1/2″ (38.1 mm) | Polypropylene | Autoclave or gamma |
Standard pack: 10 units per part number.
Industries
Pharmaceutical and biotechThe clamp-to-hose-barb connector (CHB4 to CHB8), the clamp (CLC7 or CLC10), the silicone gasket (JC-0075-SIL or JC-0150-SIL), and the end cap (CBL7 or CBL10) to close unused ports. They are ordered by part number, in packs of 10.
Yes. The clamps and gaskets can be used with both plastic and metal components.
Yes. The silicone gaskets are reusable or single-use, depending on what the process requires.
All parts can be autoclaved at 121 °C or gamma irradiated at 25 to 45 kGy.
AgileConnect line
Y and X connectors and straight reducers to branch, join, and adapt tubing lines
Connecting and disconnecting sterile lines with a quarter-turn closure
Distribution from a single port to several lines, with one on/off valve per way
Female Luer and syringe connectors for connecting devices and taking samples
Pinch clamps, metal sleeve, and nylon cable ties to close off and secure tubing lines
Talk to engineering
Tell us the fluid, the flow rate and the operating conditions. We reply with the model, the ordering code and the technical documentation.