SaniFlow STE-DO
Process filtration with one DOE cartridge, for food, beverage and pharma
- 10″–40″
Filter housings
316L multi-element filter housing
High-flow filtration for regulated pharmaceutical and biotech processes
316L stainless steel sanitary filter housing for 3 to 36 cartridges, interior Ra ≤ 0.4 µm, ASME BPE design, 3.1 certificate and SIP at 121–135 °C.
The SaniFlow STU-X is an AISI 316L stainless steel sanitary filter housing that holds multiple cartridges, designed for the requirements of the pharmaceutical and biotech industries. The standard code covers 3, 6, 9, 12, 16, 22, 24 or 36 cartridges from 10″ to 40″, on a double O-ring seat plate that lets you scale up flow with the same sealing configuration.
The design follows ASME BPE guidelines: geometry without dead zones, generous internal radii, polished orbital welds and an interior polished to Ra ≤ 0.4 µm. The bowl bottom slopes toward the drain, with a vent at the high point and a drain at the low point, and the housing withstands repeated clean steam sterilization cycles at 121–135 °C.
Connections are clamp only, from 1 1/2″ to 4″: threaded and flanged joints are not offered, because they leave non-drainable crevices, and neither are DOE cartridges, which do not provide a positive seal between the dirty side and the clean side. Every unit is passivated and hydrostatically tested, and is supplied with a 3.1 heat certificate per EN 10204 and a passivation certificate.
No dead zones, with generous internal radii and polished orbital welds that make cleaning validation easier.
Sanitary mechanical polish that reduces anchoring points for bioburden and limits biofilm formation.
Product-contact parts in AISI 316L, with a 3.1 heat certificate per EN 10204 and traceability of materials and welds.
Withstands repeated cleaning and sterilization cycles without compromising the sealing geometry.
Bottom sloped toward the drain and minimal residual volume; vent at the high point and drain at the low point.
Material, passivation and hydrostatic test certificates, with optional IQ/OQ protocols to qualify the equipment on site.
| Product-contact parts | AISI 316L |
|---|---|
| Frame and legs | AISI 304 or 316L, per specification |
| Interior finish | Ra ≤ 0.4 µm (sanitary mechanical polish) |
| Exterior finish | Ra ≤ 0.8 µm |
| Gaskets and elastomers | Platinum-cured silicone, EPDM, Viton or PTFE-encapsulated Viton, compliant with FDA 21 CFR 177 and USP Class VI |
| Quantity | 3, 6, 9, 12, 16, 22, 24 or 36; more elements on request |
|---|---|
| Diameter | 2 1/2″ (standard cartridge) |
| Configurations | B: 2 × 226 O-rings + fin · C: 2 × 222 O-rings + fin · D: 2 × 226 O-rings + flat end · E: 2 × 222 O-rings + flat end |
| Lengths | 10″, 20″, 30″ and 40″ |
| Seat | Double O-ring seat plate |
| Inlet and outlet | Clamp per ASME BPE: 1 1/2″, 2″, 2 1/2″, 3″ and 4″ |
|---|---|
| Vent and drain | Diaphragm valve, clamp 1 1/2″ or clamp 2″ |
| Operating pressure | Up to 10 bar (150 psig); calculation per ASME Section VIII Div. 1 on request |
|---|---|
| Operating temperature | −10 °C to 150 °C (14 °F to 300 °F), depending on the elastomer |
| Sterilization | SIP cycles with clean steam at 121–135 °C |
| Tests | Chemical passivation and hydrostatic testing of 100 % of units |
|---|---|
| Certificates | 3.1 heat certificate per EN 10204 and passivation certificate |
| Qualification | Optional IQ/OQ protocols |
| Bottom support | With legs |
|---|
Product selection
Pick each option and the code builds itself. With the code, the quote comes back faster and without back-and-forth.
Industries
Pharmaceutical and biotechBecause a double open end cartridge does not provide a positive seal between the dirty side and the clean side. The STU-X accepts only cartridges with a 226 or 222 double O-ring (configurations B, C, D and E).
Threaded and flanged joints leave non-drainable crevices. That is why the STU-X is offered with clamp connections per ASME BPE, in 1 1/2″, 2″, 2 1/2″, 3″ or 4″.
Every unit ships with a 3.1 heat certificate per EN 10204, a passivation certificate and a hydrostatic test report. The elastomers have an FDA 21 CFR 177 and USP Class VI declaration of conformity, and IQ/OQ protocols are available for on-site commissioning.
Yes. It is designed for repeated cleaning and sterilization cycles with clean steam at 121–135 °C without compromising the sealing geometry. The operating range is −10 °C to 150 °C, depending on the elastomer.
3, 6, 9, 12, 16, 22, 24 or 36 cartridges from 10″ to 40″, on a double O-ring seat plate. It can be customized for a larger number.
SaniFlow line
Process filtration with one DOE cartridge, for food, beverage and pharma
Sanitary liquid filtration in food and beverage production
High-flow sanitary filtration for food, beverages, wine and drinking water
Bag filtration for high solids loads, in water and fuels
Housings for 6″ High Flow cartridges, 17 to 250 m³/h recommended per housing
Low- and medium-volume filtration of liquids and gases for pharma and biotech
Technical blog
AISI 304 vs. 316L stainless steel in sanitary equipment: molybdenum, carbon and welding, chlorides, passivation, Ra finish, and when to use each one.
How to choose a sanitary filter housing: service, cartridges, 304 or 316L steel, Ra finish, connections, pressure, sterilization, and documentation.
Talk to engineering
Tell us the fluid, the flow rate and the operating conditions. We reply with the model, the ordering code and the technical documentation.